Product Description

Office Chairs Stools and Gas Springs Swivel Test Rig

Product Info

Minorder 1
Packaging Each set universal tensile test machine protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside.

Product Detail

Office Chairs Stools and Gas Springs Swivel Test Rig

Equipment Description

Test rig for rotation testing on seating furniture according to EN 1335, EN14073-2, DIN 38878 and BIFMA X5.1, load controlled with loading pad. The pneumatic test axis operates from PLC.

 

GENERL SPECIFICATIONS

Machine Dimensions: (W x D x H) 1680*890*1840mm

Power supply source: single-phase, AC220V±10%, 50/60Hz (can be appointed)

Gross Weight: 400kg


APPLICATION STANDARDS:

EN 1335, EN14073-2, DIN 38878 and BIFMA X5.1

Reference Doc: EN 1335 Swivel Test

EN1335 Chair Loading Points 


EN 1335 Chair Swivel Test Procedure:

The base of the chair shall be secured on a rotating table with a test surface so that the rotating axis of the chair coincides with the rotating axis of the table. The upper part of the chair shall be loosely fixed in such a way as not to hinder the rotation of the base. Load the seat in loading point A with a mass 60 KG and in loading point with a mass 35KG or any equivalent loading which will result in the same downwards force and bending moment on the chair. The angle of rotation shall be 360° at a rate of (10 ± 5) cycles/minute, 120,000 cycles. Change direction after each rotation.

 

EN 1335 Positioning of Chair components

Clause

Test

Seat Height

Seat

Back rest in height

Back rest in depth

Tilt stiffness adjustment

Castors and base

Arm rest

Foot rest

7.3.3

Swivel test

Highest position

Horizontal foremost position

Highest position

Rearmost position

-

-

-

-

 

EN 1335 Smaller seat loading pad (Optional Accessories) 




Reference Doc: BIFMA X5.1 Swivel Test

Chair Test Step


a) The chair shall be restrained on a platform. Either the seat or the platform shall be restrained from rotation.

b) If the seat adjustable, set it to the maximum seat position. Set all other adjustable features to the normal use condition.

c) A 113 Kg (250 lb) load shall be placed on the seat such that the centre of gravity of the load is 51 to 64 mm (2 to 2.5 in) forward of the centerline of the rotational axis as shown in Picture 1.

d) The cycling device shall be adjusted to rotate the lesser of the following: the available range of rotation or 360 degrees ± 10 degrees. If the available range of rotation is less than 360 degrees, the rotation of the test machine shall be adjusted such that the swivel mechanism touches but does not override the stops. The rotation may be either bidirectional or unidirectional.

e) For chairs that swivel 360 degrees, a cycle is one full rotation. For chairs that swivel less than 360 degrees, one cycle is rotating from one stop to the other stop.

f) The seat or platform shall rotate for 60,000 cycles at a rate between 5 and 15 rotations per minute.

g) If the seat height is adjustable set the height to its lowest position.

For all chairs, continue the test for an additional 60,000 cycles to a total of 120,000 cycles.  